Main Characteristics:
EC type-examination certificate in conformity with
• 2014/32/EU (MID) MI-001 Water Meter
• OIML R49-1 :2006
• EN 14154:2005+A2
• ISO 4064:2015
• EC Type Examination Certificate (TCM-142/14 - 5171)
• The Quality Assurance of Production Process (Module D)
• ISO 9001:2015
• ISO 14001:2015
• ISO 45001:2018
• ISO 27001:2013
Dimension | Nominal Diameter | DN | mm | 40 |
Size | Inch | 1 1/2'' | ||
Overall Lenght Without Connectors | L | mm | 300 | |
Overall Lenght With Connectors | L1 | mm | 375 | |
Thread Meter GxB | D | Inch | 2'' | |
Thread Connector | d | Inch | 1 1/2'' | |
Total Height | H | mm | 153 | |
Total Height (With Lid) | H1 | mm | 263 | |
Width Approx | W | mm | 123 | |
Weight | Weight Approx | * | kg | 1,22 |
Package Without Connectors | * | kg | 1,32 | |
Package With Connectors | * | kg | 1,60 | |
Box Dimension (1 Unite) | * | cm | 31x17x14 | |
Package Dimension (10 Unite) | * | cm | 44x33x20 | |
Quantity Per Package | * | unite | 3 | |
Threading : EN ISO 228-1 : 2003 |
Performance Data | Metrological Data | Nominal Daimeter | DN | mm | 40 | |||
Size | Inch | 1 1/2'' | ||||||
Maximum Flow Rate (m3/h) | Q4 | ≤20,00 | ||||||
Nominal Flow Rate (m3/h) | Q3 | ≤16,00 | ||||||
Transitional Flow Rate (m3/h) ±2% | Q2 | ≥0,320 | ||||||
Minimum Flow Rate (m3/h) ±5% | Q1 | ≥0,200 | ||||||
Measuring Range - Horizantal (R) | Q3 / Q1 | R80 (Class B) | ||||||
Measuring Transitional Flow Rate | Q2 / Q1 | 1,6 | ||||||
Measuring Maximum Flow Rate | Q4 /Q3 | 1,25 | ||||||
Accuracy Class | 2 | |||||||
Technical Data | Maximum Permissible Error For The Lower Flow Rate Zone | (MPE1) | ±5% | |||||
Maximum Permissible Error For The Upper Flow Rate Zone | (MPEU) | ±2 % for water having a temp. ≤30°C ±3 % for water having a temp. >30°C | ||||||
Temperature Class | T °C | T30 and T50 | ||||||
Water Pressure Classes | MAP (Bar) | 16 | ||||||
Pressure - Loss Classes | ∆ P (Bar) | 0,63 | ||||||
Max. Indicating Range | m3 | 999 999 | ||||||
Resolution Of Indicating Device | [m3] | 0,00005 | ||||||
Instalation Positions | Horizontal | |||||||
Flow Profile Sensitivity Classes | U0 , D0 | |||||||
Impulse Value | litre/pulse | 100, 1000 | ||||||
Module Type (Optional) | Pulse, MBus (Wired, Wireless), RF, AMR |
MATERIAL | ||||||
1 | BODY (PLASTIC) | |||||
2 | LID AND REGISTER CAP (PLASTIC) | |||||
3 | GASKET | |||||
4 | GLASS | |||||
5 | REGISTER | |||||
5.1 | ANTIMAGNETIC METAL RING | |||||
6 | GASKET | |||||
7 | TURBINE / VANE WHEEL | |||||
8 | MEASURING CHAMBER | |||||
9 | ADJUSTING PLUG | |||||
10 | ADJUSTING SCREW | |||||
11 | STRAINER | |||||
12 | CHECK (NON-RETURN) VALVE |