+90 212 879 10 30 info@turkoglumeters.com

ZZZ-A DN20 (3/4'') R100 / Class B

I want to be informed

Main Characteristics:

  • Approved in accordance with MID
  • Multi-Jet dry dial register type with vane-wheel
  • Brass housing material
  • Durable internal removable strainer and non return valve
  • Removable measuring mechanism
  • Metrological range -horizontal- R100 (Class B)
  • Horizontal installation
  • Magnetic transmission
  • Register cap made of brass
  • High resistance to water impurities
  • Hermetically sealed register (IP68)
  • Available for optical direct reading
  • Electrostatic e/p powder painted
  • External adjustable screw
  • Water temperature up to 50 °C
  • Spare parts and service available for 10 years
  • 2 years of guarantee

EC type-examination certificate in conformity with

• 2014/32/EU (MID) MI-001 Water Meter
• OIML R49-1 :2006
• EN 14154:2005+A2
• ISO 4064:2015

• ISO 9001:2015
• ISO 14001:2015
• ISO 45001:2018
• ISO 27001:2013

Performance Data Metrological Data Nominal Daimeter  DN mm 20
Size Inch 3/4''
Maximum Flow Rate (m3/h) Q4 ≤3,13
Nominal Flow Rate (m3/h) Q3 ≤2,50
Transitional Flow Rate (m3/h) ±2% Q2 0,040
Minimum Flow Rate (m3/h) ±5% Q1 ≥0,025
Measuring Range - Horizantal (R) Q3 / Q1 R100 (Class B)
Measuring Transitional Flow Rate Q2 / Q1 1,6
Measuring Maximum Flow Rate Q4 /Q3 1,25
Accuracy Class 2
Technical Data Maximum Permissible Error For The Lower Flow Rate Zone (MPE1) ±5%
Maximum Permissible Error For The Upper Flow Rate Zone (MPEU) ±2 % for water having a temp. ≤30°C  ±3 % for water having a temp. >30°C
Temperature Class T °C T30 and T50
Water Pressure Classes MAP (Bar) 16
Pressure - Loss Classes ∆ P (Bar) 0,63
Max. Indicating Range m3 99 999
Resolution Of Indicating Device [m3] 0,00005
Instalation Positions Horizontal 
Flow Profile Sensitivity Classes U0 , D0
Impulse Value litre/pulse 1, 10, 100, 1000
Module Type (Optional) Pulse, MBus (Wired, Wireless), RF, AMR

I Want E-Catalog

Your cart has been successfully updated